Please note we cannot control the OD of unsanded filament tubing as tightly as the sanded filament tubing. The listed OD is a theoretical value.
Let your capacity and delivery time concerns wash away. Rock West has 19 spindles on 4 separate winding machines allowing us to produce tubes in lengths up to 230". If this diameter is not a perfect match for your needs, and/or you have unique torque transfer requirements be sure to let us know. We build these parts right here in the USA.
| Application | Torque |
|---|---|
| Shape | Round |
| Materials | Standard Modulus Carbon |
| Pattern | Filament Wound |
| Color | Black |
| Finish | Cello Wrap Gloss |
| Inside Diameter | 3.0 |
| Outside Diameter | 3.28 |
| Wall Thickness | 0.140 |
| Length | 12 |
| Length (max continuous) | 144.0 |
| Linear Density | 0.911 |
| Volumetric Density | 0.055 |
| Weight | 10.938 |
| Primary Fiber | Grafil 34-700 |
| Primary Resin / Hardener | EPON 862/Lindride 6k |
| HTS - Harmonized Tariff Code | 6815.13.0000 |
All laminate properties and mechanical calculations are based on Classical Lamination Theory and should be used as a reference only. Rock West Composites does not guarantee these properties or calculations.
| Avg EX Young's Modulus | 8089000.0 |
|---|---|
| Avg EY Young's Modulus | 5360000.0 |
| GXY Shear Modulus | 4061000.0 |
| X Tensile Yield Strength | 40310.0 |
| X Compressive Yield Strength | 45650.0 |
| Y Tensile Yield Strength | 31270.0 |
| Y Compressive Yield Strength | 37230.0 |
| XY Shear Strength | 40700.0 |
| CTEX | 8.45E-08 |
| CTEY | 1.45E-06 |
| Poisson's Ratio vXY | 0.493 |
| Poisson's Ratio vYX | 0.327 |
All laminate properties and mechanical calculations are based on Classical Lamination Theory and should be used as a reference only. Rock West Composites does not guarantee these properties or calculations.
| Ply # | Orientation (degrees) | Location |
|---|---|---|
| 1 | ±45 | Inside |
| 2 | ±15 | ↓ |
| 3 | ±45 | |
| 4 | Hoop | |
| 5 | ±45 | |
| 6 | ±15 | |
| 7 | ±45 | |
| 8 | (Hoop-Fiberglass) | Outside |
This specific SKU 35153-GTRQ was tested with bonded in yokes and using SFI Specification 43.1. The specification requires these tubes to be tested to a static torque of 2800 lb/ft for 10 seconds and then tested with a cyclic torque of +2500 lb/ft and –1000 lb/ft for 25 cycles. After static and cyclic testing was performed, a destructive failure test was performed and resulted in the sample average torsional strength being 5773 lb/ft. Failure occurred when the adhesive broke and caused the yoke to slip inside the tube. This failure mode was unsatisfactory to us so we decided to insert 2 - ¾” bolts through each of the bonded in yokes and carbon. This test resulted in a slightly higher strength and failure was caused by the adhesive breaking and the bolts being ripped through the carbon.