When selecting a ferrule for your project you will want to select a ferrule that is 0.010" smaller on the outer diameter than the inner diameter measurement of the tubes you are joining. You will also want to verify that the ferrule wall thickness is equal to or greater than the tubes you are joining.
P/N | 45626-F5.5 |
---|---|
Application | Joining Tubes |
Finish | Sanded Smooth |
HTS - Harmonized Tariff Code | 6815.13.0000 |
Inside Dimension | 0.75 |
Length | 5.5 |
Materials | Standard Modulus Carbon |
Temperature Rating (F) | 238.0 |
OD | 0.865 |
Outside Dimension | 0.865 |
Tensile Modulus, msi | 13.57 |
Thickness | 0.058 |
Weight | 0.08 |
Theoretical Test Data |
||
SKU: 45626-F Rev A |
||
Ftu-Lengthwise | 125 | ksi |
Tension Strength | 19.5 | k-lb |
Fcu-Lengthwise | 76 | ksi |
Compression Strength | 11.9 | k-lb |
Flexure Strength | 76 | ksi |
Internal Pressure | 2290 | psi |
Tension Modulus | 12.1 | Msi |
Compression Modulus | 11.8 | Msi |
*ALL data in this table provided as reference only. Rock West does not guarantee values presented herein and requires that physical testing & validation be performed by purchaser prior to product assembly or use.
SKU: 45626-F Rev A |
||
Ply # | Orientation | Location |
1 | 0 | Inside |
2 | 0 | ↓ |
3 | 0 | |
4 | 90 | |
5 | 90 | |
6 | 90 | |
7 | 90 | |
8 | 0 | |
9 | 0 | |
10 | 0 | |
11 | 0 | Outside |